200 AMP BREAKER SQUARE D CODE

Range PowerPact product name PowerPact J Product or Component Type Circuit breaker Device Application Distribution Line Rated Current 200 A Number of Poles 3P Control Type Toggle breaking capacity code G breaking capacity 65 kA 240 V AC 50/60 Hz UL 489 35 kA 480 V AC 50/60 Hz UL 489 18 kA 600 V AC 50/60 Hz UL 489 20 kA 250 V DC UL 489 20 kA 500 V DC UL 489 rated operational voltage 600 V AC 50/60 Hz IEC 60947-3 Network Frequency 50/60 Hz rated service breaking capacity 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 20 kA 250 V DC IEC 60947-2 20 kA 500 V DC IEC 60947-2 rated impulse withstand voltage 8 kV IEC 60947-2 trip unit technology Thermal-magnetic magnetic tripping current 2000 A magnetic hold current 1000 A continuous current rating 80 % rated insulation voltage 750 V IEC 60947-2 Protection Type Overload protection Short-circuit protection suitability for isolation Yes IEC 60947-2 utilisation category Category A AWG gauge AWG 3/0.350 kcmil aluminium/copper terminals local signalling Switched off (OFF) 1 trip indicator green) mounting mode Unit mount lug) Mounting Support Lug electrical connection Lugs line Lugs load terminal identifier AL250JD long time pick-up adjustment range 0.25.1 x In Mounting Height 4.5 in (114.30 mm) tightening torque 221.27 lbf.in (25 N.m) 0.15…0.29 in² (95…185 mm²) (AWG 3/0.350 kcmil) number of slots 2 auxiliary switch OF plug-in) 1 alarm switch SD plug-in) 1 overcurrent trip switch SDE plug-in) 1 voltage release MN or MX plug-in) Power wire stripping length 0.98 in (25 mm) Height 7.52 in (191 mm) Width 4.09 in (104 mm) Depth 3.39 in (86 mm) Net Weight 5.29 lb(US) (2.4 kg) phase connection ABC communication interface Modbus Ethernet circuit breaker application HACR rated quality labels CE Standards UL CSA NEMA NOM-003-SCFI-207-2 product certifications UL CSA NOM IP degree of protection Front cover IP40 pollution degree 7-1 Ambient air temperature for operation 28…158 ☏ (-2…70 ☌) Ambient Air Temperature for Storage -58…185 ☏ (-50…85 ☌) operating altitude < 6561.68 ft (2000 m) without derating 5000 m with derating Category 01115-HG HJ JG JJ UNIT MT BREAKER/SWITCH Discount Schedule DE2 GTIN 785901683216 Returnability Yes Country of origin MX Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.40 in (18.796 cm) Package 1 Width 5.70 in (14.478 cm) Package 1 Length 8.70 in (22.098 cm) Package 1 Weight 4.80 lb(US) (2.All our reconditioned circuit breakers and repairs conform to NETA, UL 1066, UL 489, and ANSI C37 specifications.

200 amp breaker square d

PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. This circuit breaker has a continuous current rating of 80%. This PowerPacT J, 200A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This breaker has lugs on both the line and load sides. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault.

200 amp breaker square d

This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. Molded Case Circuit Breaker, 200 Amp, 3 Pole, 600 Volt PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits.








200 amp breaker square d